Hello all,
When attempting to connect to Teradata 14.10, I am receiving the following error message:
Warning: RDBMS Crashed or Sessions reset. Recovery in Progress
After ctrl-c'ing a coupe of times, I get sent back to the BASH prompt.
While attempting to connect, I tailed the messages log in /var/log....and found the following lines..
....
Apr 12 11:59:14 prteradata Teradata[5783]: INFO: Teradata: 13815 #Event number 33-13815-00 (severity 10, category 12)
Application not started because all AMPs are in NewProc or Fatal state.
Apr 12 12:08:11 prteradata Teradata[6555]: INFO: Teradata: 15070 #PDISK 1 has incorrect device number 0 in its tag
Apr 12 12:08:11 prteradata Teradata[6555]: INFO: Teradata: 15070 #PDISK 0 has incorrect device number 1 in its tag
So, I read somewhere to run vprocgdo...and received the following results...
Vpr: VprocID Clq Type Movable NodeID Vdisk CUA HGID Slot Status Err
0: 0 0 1 Y 001-01 0 -1 -1 -1 FATAL E
1: 1 0 1 Y 001-01 1 -1 -1 -1 FATAL E
2: 16383 0 2 Y 001-01 16383 -1 1 56 ONLINE N
3: 8192 0 3 N 001-01 8192 -1 1 56 ONLINE N
4: 9215 0 4 N 001-01 9215 -1 1 56 ONLINE N
5: 10237 0 5 Y 001-01 10237 -1 -1 -1 ONLINE N
6: 10238 0 5 Y 001-01 10238 -1 -1 -1 ONLINE N
...df -h shows....
ilesystem Size Used Avail Use% Mounted on
/dev/sda2 14G 6.8G 6.4G 52% /
devtmpfs 873M 132K 873M 1% /dev
tmpfs 873M 100K 873M 1% /dev/shm
/dev/sda5 2.0G 564M 1.4G 30% /var
/dev/sda7 41G 734M 38G 2% /var/opt/teradata
lx_share 466G 142G 325G 31% /media/sf_lx_share
Can anyone on the forum point me in the right direction on how to correct these fatals?
FYI. I come from a heavy Oracle/MySQL Administration background and am now trying to learn Teradata. So, these errors are not in a prod env, however, I would like to get past
these so that I can get acquainted with the internals of Teradata.
Thanks in advance,
pruiz